Diff-Therm Platen Heaters for Vacuum Diffusion Pumps

28 Hayward St., Ipswich, MA 01938
Tel: 1-978-356-9844, Fax: 1-978-356-9846
www.DaltonElectric.com

We are an authorized distributor for Dalton Electric Heating Company, Inc., who began manufacturing Diff-Therm Diffusion Pump Heaters in 1958. Today, Diff-Therm heaters are the replacement heater of choice for vacuum OEM diffusion pump users.

The Diff-Therm heater is a combination of high-quality, tubular heating elements and grey iron castings (platens and rings) swaged together under 50 tons per square inch pressure. For over twelve years of service to the vacuum industry in the United States and Canada, these heaters have been the industry standard for long life, for uniformly distributed process heat, and for efficient power generation.

Dalton Electric Heating manufactures stock Diff-Therm heaters for 2" through 48" Diffusion Pumps in over 100 combinations of electrical ratings and casting sizes. They also manufacture Diff-Therm heaters in custom casting dimensions and electrical ratings for use on obsolete and foreign-made pumps.

In summary, Diff-Therm heaters provide you with...

They are the proven, industry standard.

Illustrations 1 and 2 below tell the story of Diff-Therm's performance superiority over other, bolt-on Diffusion Pump heaters. Dalton manufactures tubular heating elements using only high purity magnesium oxide, nickel chrome resistance wire and stainless steel terminals for internal components. Special filling equipment and methods compact the magnesium oxide inside and around the resistor helix to extreme density which, coupled with swaging, gives Diff-Therm heating elements high dielectric strength and efficient internal heat conduction. These properties are then maximized as the heating elements are further compacted by being swaged into undercut grooves in the Diff-Therm castings. This process locks the heating elements into con-tact with the castings, creating uniform heat conduction into the castings along the entire length of the grooves.

The surface of a Diff-Therm casting, which will be in contact with the Diffusion Pump boiler plate, is machined to a flat, smooth finish. When the assembled heater is bolted onto the Pump, heat is conducted efficiently and uniformly into the boiler plate for a steady vaporization of the Pump fluid.


Illustration 1


Illustration 2

Selection Chart:

Platen
Number
2/9D
Platen
Number
4D
Platen
Number
5D
Platen
Number
3/2D
Platen
Number
4/2D
Platen
Number
5/5D
Platen
Number
3/3D
Platen
Number
4/9D
Platen
Number
6D
Platen
Number
6/5D
Platen
Number
7/3D
Platen
Number
10R
Platen
Number
6/9D
Platen
Number
8R
Platen
Number
10/9D
Platen
Number
7D
Platen
Number
8/2R
Platen
Number
11D
Platen
Number
12D
Platen
Number
15R
Platen
Number
12/3 RI
(typical)
Platen
Number
14R
Platen
Number
16/8R

Selector Index:

Diffusion Pump Manufacturer1 Platen Number Platen Diameter (D) or Radius (R)2 Number of Heating Elements in Platen Location of Heating Element Terminals3
CVC Products 2/9D  2 15/16"-D One Inside - 90º
Denton Vacuum, High Vacuum Equipment 3/2D 3 1/4"-D One Outside - 0º
Perkin-Elmer 3/3D 3 5/16"-D One Inside - 90º or 45º
Varian/NRC, Edwards High Vacuum 4D 4 1/32"-D One Outside - 0º
Perkin-Elmer 4/2D 4"-D One Inside - 90º or 45º
Varian/NRC, CVC Products, Edwards High Vacuum 4/9D 4 7/8"-D One Outside -  0º
Varian/NRC, High Vacuum Equipment, Torr Vacuum 5D 5 1/8" -D One Outside -  0º
Cooke Vacuum Products 5/5D 5 1/2"-D One Inside - 45º
Varian/NRC, Edwards High Vacuum 6D 6"-D One Outside -  0º
CVC Products 6/5D 6 1/2"-D One Inside - 90º
CVC Products, Edwards High Vacuum 6/9D 6 15/16"-D One Outside - 0º
Varian/NRC, High Vacuum Equipment, Torr Vacuum 7D 7"D One Outside - 0º
Cooke Vacuum Products 7/3D 7 1/2"-D One Inside - 45º
Varian/NRC 8R 8 1/4"R One Inside - 45º
CVC Products 8/2R 8"-R One Inside - 90º
Varian/NRC, Edwards High Vacuum lOR 10R 9 1/4"-R One Inside - 45º
CVC Products 10/9D 11 1/16"-D Three Inside - 45º
Varian/NRC, Torr Vacuum 11D 10 15/16"-D Three Inside - 45º
Varian/NRC 12D 12 1/2"-D Two Inside - 45º
Varian/NRC 14R 14 1/4"-D Two Inside - 45º
Varian/NRC 15R 14 1/4"-R One Inside - 45º
Varian/NRC 16/8R 16 1/2"-R One Inside - 45º

1. Dill-Therm Heaters originally designed for Diffusion Pumps of these manufacturers.
2. Radii listed above are measured between apex of the angle formed by extending Platen sides to a point and outside edge of Platen (see illustrations).
3. "Inside" and "Outside" relate terminal locations to the Platen perimeters. The angles listed are between the terminals and the surfaces of the Platens.


Copyright © 1997-2001 Dalton Electric Co., Inc. All Rights Reserved. Used with permission of Dalton Electric Co., Inc.

Home ] Up ]

We are a Distributor of Industrial, Commercial and Residential Heaters and Controls. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc.

MOR ELECTRIC HEATING ASSOC., INC.
5880 Alpine Ave. NW - Comstock Park, MI 49321  USA
Tel 616-784-1121 - 800-442-2581 - Fax 616-784-7775
E-mail: sales@heatersplus.com

   follow our blog   Find us on FaceBook   watch our youtube channel   Follow us on Twitter