HBControls S Series DIN Rail Mount Solid State Relay Assemblies to 25 Amps

HBControls Solid State Relay Assemblies We are an authorized distributor for HBControls

SSR DIN Rail Mount to 25 Amps AC @ 40°C Ambient

FEATURES:
• Standard relays approved to the following: UL, CSA, VDE and CE
• Finger-safe cover standard
• Zero voltage switching standard
• Optional random turn-on available (-10)
• Optional Voltage transient protection (MOV) available (-M)
• Optional LED input status indicator available, (-Z)
• 24 VAC input available (-E)

 

Features:
- Solid State Relay Assemblies rated to 25A/pole @ 40° C (100% duty cycle)

- Available in 1, 2 & 3 Pole configurations

- Relays approved to the following: UL, CSA, VDE and CE

- Zero cross switching standard

- Compact heat sink design for space limited applications

- Finger safe cover standard

- Phase angle & time proportioning control optional

 

NOTES:

1) Heat sink black anodized aluminum
2) All dimensions in inches
3) Consult HBControls for application information
4) Cover adds approx. 0.4" to assembly height

Single Phase Relay Wiring Diagram:

OUTPUT SPECIFICATIONS AC Control
 
HBC-25AS
 
HBC-25HAS
 
HBC-625AS
 
HBC-50AS
 
HBC-50HAS
 
HBC-650HAS
 
Operating Voltage  (47-63 Hz) [Vrms]
24-280
48-530
24-280
48-530
48-530
48-660
Load Current Range [Arms]
.04-15
.04-15
.04-15
.04-25
.04-25
.04-25
Transient Overvoltage [Vpk]
600
1200
1200
600
1200
1200
Max. Surge Current, (16.6ms) (Apk)
250
250
250
625
625
625
Max. On-State Voltage Drop  [Vpk]
1.6
1.7
1.7
1.6
1.7
1.7
Max. Turn-on Time (mS)
10
10
10
10
10
10
Max. Turn-off Time (mS)
40
40
40
40
40
40
Max.I²t for fusing  (8.3mS)
260
260
620
1620
1620
1620
Max. Off-State Leakage Current [mArms]
10
10
5
10
10
5
Power Factor  (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
 
Control Voltage Range [Vrms]
90-280
90-280
90-280
90-280
90-280
90-280
Max. Turn-on Voltage [Vrms]
90
90
90
90
90
90
Min. Turn-off Voltage [Vrms]
10
10
10
10
10
10
Nominal Input Impedance [Ohms]
60K
60K
60K
60K
60K
60K
Typical Input Current
2mA @ 120Vrms, 4mA @ 240Vrms
OUTPUT SPECIFICATIONS
DC Control
 
HBC-25DS
 
HBC-25HDS
 
HBC-6250DS
 
HBC-50DS
 
HBC-50HDS
 
HBC-650HDS
 
Operating Voltage  (47-63 Hz) [Vrms]
24-280
48-530
24-660
48-280
48-530
48-660
Load Current Range [Arms]
.04-15
.04-15
.04-15
.04-25
.04-25
.04-25
Transient Overvoltage [Vpk]
600
1200
1200
600
625
1200
Max. Surge Current, (16.6ms) (Apk)
250
250
250
625
625
625
Max. On-State Voltage Drop  [Vpk]
1.6
1.7
1.7
1.6
1.7
1.7
Max. Turn-on and Turn-off Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Max.I²t for fusing  (8.3mS)
260
260
260
1620
1620
1620
Max. Off-State Leakage Current [mArms]
10
10
5
10
10
5
Power Factor  (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
 
Control Voltage Range [Vdc
3-32
3-32
3-32
3-32
3-32
3-32
Max. Turn-on Voltage [Vdc]
3.0
3.0
3.0
3.0
3.0
3.0
Min. Turn-off Voltage [Vdc]
1.0
1.0
1.0
1.0
1.0
1.0
Nominal Input Impedance [Ohms]
1500
See *
See *
1500
See *
See *
Typical Input Current
 
2.0mA *
2.0mA *
3.4mA @ 5Vdc, 20mA @ 28Vdc
2.0mA *
2.0mA *
*  Input circuitry incorporates active current limiter
 

Secure Online Ordering
Delivery time for the following products: Typically processed/shipped in 7-10 working days or less.  The transit time to you depends on your selected UPS/FedEx shipping method, the cost of which will be displayed in your shopping cart.

Item ID

Catalog # Description

Click "Select" below

HBC10030 HBC-25DS 3-32 VDC Control Input - 24-280 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10060 HBC-50DS 3-32 VDC Control Input - 24-280 VAC Line Voltage Range - 0.04-25 Load Current. Select
HBC10061 HBC-25AS 90-280 VAC Control Input - 24-280 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10062 HBC-50AS 90-280 VAC Control Input - 24-280 VAC Line Voltage Range - 0.04-25 Load Current. Select
HBC10063 HBC-25HDS 3-32 VDC Control Input  - 48-530 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10064 HBC-50HDS 3-32 VDC Control Input  - 48-530 VAC Line Voltage Range - 0.04-25 Load Current. Select
HBC10065 HBC-25HAS 90-280 VAC Control Input - 48-530 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10066 HBC-50HAS 90-280 VAC Control Input - 48-530 VAC Line Voltage Range - 0.04-25 Load Current. Select
HBC10067 HBC-625HDS 3-32 VDC Control Input  - 48-660 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10068 HBC-650HDS 3-32 VDC Control Input  - 48-660 VAC Line Voltage Range - 0.04-25 Load Current. Select
HBC10069 HBC-625HAS 90-280 VAC Control Input - 48-660 VAC Line Voltage Range - 0.04-15 Load Current. Select
HBC10070 HBC-650HAS 90-280 VAC Control Input - 48-660 VAC Line Voltage Range - 0.04-25 Load Current. Select

Home ] Up ]

We are a Distributor of Industrial, Commercial and Residential Heaters and Controls. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc.

MOR ELECTRIC HEATING ASSOC., INC.
5880 Alpine Ave. NW - Comstock Park, MI 49321  USA
Tel 616-784-1121 - 800-442-2581 - Fax 616-784-7775
E-mail: sales@heatersplus.com

   follow our blog   Find us on FaceBook   watch our youtube channel   Follow us on Twitter