Eemax Three Phase Tankless Instantaneous Water Heaters

Eemax Electric Tankless Instantaneous Water Heaters
We are a distributor for Eemax Inc.

The Eemax "Three Phase" range are high powered instantaneous water heaters from 18kW through 32kW. They are ideally suited for higher flow rate industrial/commercial applications.

Ideal for wash down

stations and production

lines.

Eemax "Three Phase" water heaters are very compact in size and can be installed in out of the way or cramped locations.

The plumbing connections are 1/2" compression and require no soldering.

No pressure and temperature relief valve is required. (Check local codes).

Installation in series or parallel with other Eemax units will give a higher flow rate or greater temperature rise.(2 units max.)

Eemax Inc. custom builds "Three Phase" instantaneous water heaters to many voltage specifications.


Specifications

"THERMOSTATIC"

THREE PHASE ELECTRICAL and TEMPERATURE RATINGS:

MODEL

VOLTS

kW

AMPS/phase

Temperature Rise F at /GPM

Wire Size

 

 

 

 

1.5

2.0

2.5

3.0

 AWG

EX180T3

480/277

18

22

 82º

61º 

49º 

41º 

10

EX240T3

480/277

24

29

 109º

82º

65º 

54º 

10

EX320T3

480/277

32

39

 -

109º 

87º 

73º 

8

EX180T3

208/120

18

50

82º

61º 

49º

41º 

6

EX240T3

208/120

24

67

109º

82º

65º

54º

6

Unit turns on 1.8GPM

Note: Three Phase units rated for 480/277 volts can only be connected in STAR formation, ie 5 wire including a neutral.
Three Phase units rated for 208/120 volts can only be connected in DELTA formation, ie 4 wire no neutral required.


"FLOW CONTROLLED"

THREE PHASE ELECTRICAL and TEMPERATURE RATINGS:

MODEL

VOLTS

kW

AMPS/phase

Temperature Rise F at /GPM

Wire Size

 

 

 

 

1.5

2.0

2.5

3.0

 AWG

EX180P3

480/277

18

22

 82º

61º 

49º 

41º 

10

EX240P3

480/277

24

29

 109º

82º

65º 

54º 

10

EX320P3

480/277

32

39

 -

109º 

87º 

73º 

8

EX180P3

208/120

18

50

82º

61º 

49º

41º 

6

EX240P3

208/120

24

67

109º

82º

65º

54º

6

Unit turns on 1.8GPM

Note: Three Phase units rated for 480/277 volts can only be connected in STAR formation, ie 5 wire including a neutral.
Three Phase units rated for 208/120 volts can only be connected in DELTA formation, ie 4 wire no neutral required.


"THERMOSTATIC SERIES THREE"

THREE PHASE ELECTRICAL and TEMPERATURE RATINGS:

MODEL

VOLTS

kW

AMPS/phase

Temperature Rise F at /GPM

Wire Size

 

     

1.5

2.0

2.5

3.0

3.5 4.0 5.0

 AWG

 EX180T2T

208/120  18  50 

 82º

61º

49º

41º

35º 32º 25º

6

EX240T2T

208/120

24

67

-

82º

65º

54º

47º 43º 34º

6

EX180T2T

277

18

21.7

82º

61º

49º

41º

35º 32º 25º

10

EX240T2T

277

24

28.9

-

82º

65º

54º

47º 43º 34º

10

EX320T2T 277 32 38.5 -

-

87º

73º

62º 58º 45º

8

* If the unit is connected to a 460/265 three phase system, the above outputs will be reduced by 8.5%
Unit turns on in stages, (.7GPM) turn on

Note: Three Phase units rated for 480/277 volts can only be connected in STAR formation, ie 5 wire including a neutral.
Three Phase units rated for 208/120 volts can only be connected in DELTA formation, ie 4 wire no neutral required.


               APPLICATIONS:
  • Manufacturing processes and operations. 
  • Booster 
  • Large Circular Industrial Handwash Stations.
  • Industrial Washdown Stations.
  • ADVANCED TECHNOLOGY
    HIGHEST EFFICIENCY
    DESIGNED FOR
    DURABILITY 

    QUALITY FEATURES


    SPECIFICATIONS:
    Dimensions: 12"x12"x3½"
    Weight: 12 lbs.
    Materials:
    Cover: Enameled Steel.
    Glass reinforced "NORYL"* Heater Body
    and Ni Chrome Element
    Color: White
    Element: Triple replaceable
    cartridge inserts
    Pipe-Fittings: ½" compression
    at bottom of unit
    U.S. Patent #'s: 4,960,976 and 4,762,980
    *NORYL is a registered trademark of General Electric Company

    If the unit is connected to a 460/265 three phase system, the above outputs will be reduced by 8.5%
    Rise in Temp (°F) = (KW rating x 6.83)/ GPM
    Flow Rate. (GPM) = (KW rating x 6.83)/ rise in temp (°F)

    Eemax "Three-Phase" heaters can be tailored to suit the customer's particular requirements.
    Please supply the following information when ordering:
    WATER SUPPLY CONDITIONS: mains, well pump, average incoming temperature and pressure.
    REQUIREMENTS: flow rate (gals. per min.), outlet temperature.
    AVAILABLE ELECTRICAL SUPPLY: voltage, maximum amps per phase.

       SPECIAL DESIGN SERVICE INQUIRIES FOR UNITS FOR UNIQUE APPLICATIONS ARE WELCOME.  CONTACT US.

    MODEL

    VOLTS

    kW

     

    EX320T3

    480/277

    32

     

    EX180T3

    208/120

    18

     

    EX240T3

    208/120

    24

     

    EX320P3

    480/277

    32

     

    EX180P3

    208/120

    18

     

    EX240P3

    208/120

    24

     

     EX180T2T

    208/120  18   

    EX240T2T

    208/120

    24

     
    EX320T2T 277 32  

    Home ] Up ]

    We are a Distributor of Industrial, Commercial and Residential Heaters and Controls. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc.

    MOR ELECTRIC HEATING ASSOC., INC.
    5880 Alpine Ave. NW - Comstock Park, MI 49321  USA
    Tel 616-784-1121 - 800-442-2581 - Fax 616-784-7775
    E-mail: sales@heatersplus.com

       follow our blog   Find us on FaceBook   watch our youtube channel   Follow us on Twitter