EASYHEAT SR Trace Self-Regulating Freeze Protection Cable

Link To EGS Home Page - New Window EasyHeat Heating Products 
We are an authorized distributor for
Easy Heat, Inc.


Links to other roof heating cable products:
Easy Heat ADKS Roof and Gutter Heat Trace Cable
Danfoss RX Roof & Gutter Deicing Cables.
Chromalox Commercial Grade Roof and Gutter Heat Trace Cable
ETI Heat Trace Controls
EasyHeat PSR Pre-Terminated Self-Regulating Freeze Protection Cable for Water Pipes and Roofs.
Danfoss Ice Guard Self-Regulating Roof & Gutter Deicing Cable


Links to other pipe heating cable products:
EASYHEAT ILH In-Line Inside the Pipe Heater freeze protection for water supply lines.
EasyHeat PSR Pre-Terminated Self-Regulating Freeze Protection Cable for Water Pipes and Roofs.
Danfoss Ice Guard Self-Regulating Pipe Heat Trace


EasyHeat® SRTrace®  offers a perfect solution to cold-weather-related problems. Keeping pipes from freezing or eliminating ice dams on rooftops, SRTrace is a self-regulating heating cable engineered to vary its heat output as the surrounding temperature changes. Plus, the SRTrace system includes the appropriate cable and hardware needed for either situation.

srtrace

Available in power densities of three, five and eight watts per foot. Cables are available for 120, 240, 208, or 277 VAC applications. This self-regulating cable provides the right amount of heat when and where it is needed. Because of the self-regulating feature of this cable, it can be wrapped over itself (overlapped), if necessary, when installed on pipes, valves or flanges.


"J" Jacketed Cable
SR Trace Warning Kit Eight specially designed kits provide the right hardware for properly installing SR Trace™ self-regulating heating cables.

Remember EASYHEAT's® SRTrace system when it's time to solve your cold weather problems.


Dimensions you will need:

Figure 2


NOTE:
"W" is 24" from peak to peak
"H" is based on eave overhang (See Table 2)

The cable should be installed over the unheated portion of the roof (E in Fig. 1) - normally the roof area above the overhang.

To design how much cable is needed, multiply the length of the roof edge that you want cable on by the following spacing factor:

Cable Installation Patterns:

One cable may cover both roof and gutter areas, or separate cables can be used.

Add this number calculated above to the length of the downspout. (A in Figure 2).  Note: If a downspout is located anywhere other than at the end of the cable routing, that downspout will require double length of cable (B in Figure 2).  Add extra cable for valleys (6' per valley, C in Figure 2) and around dormers (D in Figure 2)

Example: 20 feet of roof, 24" overhang (therefore using overhang multiplier of 2.7), 1 downspout @ 10' at end of cable run, 1 valley, 1 dormer with 30' perimeter.

Cable length = (28 x 2.7) + 10 + 6 + 30 = 100 feet.  Select 100 feet.  If there is excess cable it can be used in the valley or downspout.


Accessories:
Fiberglass Cloth Tape. Fiberglass cloth tape roll with a pressure-sensitive adhesive backing. Fiberglass cloth tape roll with pressure-sensitive thermosetting silicone adhesive. 365° F (185°C) rated. 3/4" (1.9 cm) wide x 108 ft. (32.91 m) long roll.
Aluminum Foil Tape. High temperature tape roll with a pressure-sensitive adhesive backing. 2" (5.08 cm) wide x 150 ft. (54.86 m) long roll, 200° F (93°C) rated.
  EASYHEAT GFST-1 120V Plug-In Power Connection Kit. EASYHEAT Line Plug to Heating Cable. Plug Adapter Kit for SR Cable with 30 Ma ground fault circuit protection. For EasyHeat SR Series self-regulating cable.

SRES End Seal Kit for Roof and Gutter Deicing and Pipe Tracing

SRSRG Roof and Gutter Splice Kit for Roof and Gutter Deicing

SRTCS Installation Kit for Pipe Tracing

SRST Splice and "T" Kit for Pipe Tracing

SRP Power Connection Kit for Roof and Gutter Deicing and Pipe Tracing

250' self dispensing reel box

Each connection kit contains detailed instructions for connecting the cable to power supplies and/or other heating cables. Since self-regulating heating cable varies its heat output in relation to the ambient temperature a thermostat may not be necessary for some freeze protection applications. This feature also allows you to overlap the cable with no more overheating worries.  As the surrounding temperature increases, the heat of the SR cable decreases. When the temperature decreases, the cable heat increases along the length of the cable.


Application Guide
Specification Sheet For Pipe
Kits and Accesorries Selection Guide
Application Guide For Pipe

General Product Information
Installation Instructions For Pipe
Specification Sheet For Roof

You must have the free Adobe Acrobat Reader plug-in.

Secure Online Ordering
*Delivery time: The items that show a stock level in the shopping cart typically ship in 1 working day or less plus allow additional time for your selected UPS or FedEx shipping method.  Your shipping cost will be displayed in your shopping cart.

Note: The cable is also available for sale by the foot below and is a custom order. Once the order is placed it cannot be cancelled or returned once you receive the cable. This is because the cable is cut to length here, or at EasyHeat, for your order, to your requested length.

Item ID Catalog # Description

Click "Select" below to see the price and our actual real-time quantity in stock

Roof and Gutter Applications:

EASY10177

SR51J

Cut-to-order, 5 w/ft, 120 VAC

Select

EASY10076

SR51J250

250' self dispensing reel, 5 w/ft, 120 volt

Select
EASY10598 SR51J750 750' self dispensing reel, 5 w/ft, 120 volt Select

EASY10149

SR52J

Cut-to-order, 5 w/ft, 208/240/277 VAC

Select

EASY10274

SR52J250

250' self dispensing reel, 5 w/ft, 208/240/277 volt

Select
EASY10585 SR52J750 750' self dispensing reel, 5 w/ft, 208/240/277 volt Select
Roof and Gutter Accessories:

EASY10056

SRP

Heat shrink power/end connection kit

Select

EASY10081

SRES

Heat shrink end seal kit (5)

Select
EASY10150 SRSRG Cable Splice kit Select
EASY10055 DSH Downspout Hanger Kit (2) Select
EASY10058 ZH-C Roof Clips and Spacers (25) Select
CHROM383355 AT-1 Roll of Aluminum Tape, 2" Wide x 150 ft Long Select
EASY10678 GFST-1 120V Plug-In Power Connection Kit Select
Wet Location Pipe Cables:

EASY10205

SR31J

3w/ft. 120 VAC. cut-to-order

Select

EASY10227

SR31J250

250' self dispensing reel, 3w/ft. 120 VAC.

Select

EASY10228

SR32J

3 w/ft, 240 VAC, cut-to-order

Select

EASY10318

SR32J250

250' self dispensing reel, 3 w/ft, 208/240/277 VAC

Select

EASY10177

SR51J

5 w/ft, 120 VAC, cut-to-order

Select

EASY10076

SR51J250

250' self dispensing reel, 5 w/ft, 120 volt

Select
EASY10598 SR51J750 750' self dispensing reel, 5 w/ft, 120 volt Select

EASY10149

SR52J

5 w/ft, 208/240/277 VAC, cut-order

Select

EASY10274

SR52J250

250 self dispensing reel,5 w/ft, 208/240/277 volt

Select
EASY10585 SR52J750 750' self dispensing reel,5 w/ft, 208/240/277 volt Select

EASY10219

SR81J

8 w/ft, 120 VAC, cut-to-order

Select

EASY10628

SR81J250

250 self dispensing reel, 8 w/ft, 120 VAC

Select
EASY10644 SR81J750 750' self dispensing reel, 8 w/ft, 120 VAC Select

EASY10229

SR82J

8 w/ft, 240 VAC, cut-to order

Select

EASY10639

SR82J250

250' self dispensing reel, 8 w/ft, 208/240/277 VAC

Select
EASY10645 SR82J750 750' self dispensing reel, 8 w/ft, 208/240/277 VAC Select
Pipe Accessories:

EASY10056

SRP

Heat shrink power/end connection kit

Select

EASY10082

SRST

Heat shrink splice and "T" connection kit (2)

Select

EASY10081

SRES

Heat shrink end seal kit (5)

Select

EASY10092

SRTCS

Fiberglass application tape and caution signs

Select
EASY10150 SRSRG Cable Splice kit Select
EASY10678 GFST-1 120V Plug-In Power Connection Kit Select
CHROM383355 AT-1 Roll of Aluminum Tape, 2" Wide x 150 ft Long Select
TAPE10004 SM431 3/4" Fiberglass Cloth Tape, 3/4" x 36 yds Select
*This delivery time is for normal conditions and is subject to EasyHeat factory availability.

EasyHeat is a registered trademark of Easy Heat, Inc.

Home ] Up ]

We are a Distributor of Industrial, Commercial and Residential Heaters and Controls. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc.

MOR ELECTRIC HEATING ASSOC., INC.
5880 Alpine Ave. NW - Comstock Park, MI 49321  USA
Tel 616-784-1121 - 800-442-2581 - Fax 616-784-7775
E-mail: sales@heatersplus.com

   follow our blog   Find us on FaceBook   watch our youtube channel   Follow us on Twitter