HeatersPlus.com Questions? 1-800-442-2581 |
Our secure online ordering website: www.MorElectricHeating.com.
|
|
Home | Ordering | Contact Us | Heaters | Controls | Accessories | Search | ||
EASYHEAT SR Trace Self-Regulating Freeze Protection Cable
We are an authorized distributor for
Easy Heat, Inc.
Links to other roof heating cable
products:
Easy Heat ADKS Roof and Gutter Heat Trace Cable
Danfoss RX Roof & Gutter Deicing Cables.
Chromalox Commercial Grade Roof and Gutter Heat Trace Cable
ETI Heat Trace Controls
EasyHeat PSR Pre-Terminated Self-Regulating
Freeze Protection Cable for Water Pipes and Roofs.
Danfoss Ice Guard Self-Regulating Roof & Gutter Deicing Cable
Links to other pipe heating cable
products:
EASYHEAT ILH In-Line Inside the Pipe Heater freeze protection for water supply lines.
EasyHeat PSR Pre-Terminated Self-Regulating
Freeze Protection Cable for Water Pipes and Roofs.
Danfoss Ice Guard Self-Regulating Pipe Heat Trace
EasyHeat® SRTrace® offers a perfect solution to cold-weather-related problems. Keeping pipes from freezing or eliminating ice dams on rooftops, SRTrace is a self-regulating heating cable engineered to vary its heat output as the surrounding temperature changes. Plus, the SRTrace system includes the appropriate cable and hardware needed for either situation.
Available in power densities of three, five and eight watts per foot. Cables are available for 120, 240, 208, or 277 VAC applications. This self-regulating cable provides the right amount of heat when and where it is needed. Because of the self-regulating feature of this cable, it can be wrapped over itself (overlapped), if necessary, when installed on pipes, valves or flanges.
"J" Jacketed Cable |
Eight specially designed kits provide the right hardware for properly installing SR Trace™ self-regulating heating cables. |
Remember EASYHEAT's® SRTrace system when it's time to solve your cold weather problems.
The cut to length design allows for easy field sizing and installation.
All power densities are available from the factory in cut to order lengths or in easy to use 250 ft. self dispensing reel boxes.
Specially designed installation and connection kits ease installation.
UL Listed
CSA certified
Dimensions you will need:
Figure 2
NOTE:
"W" is 24" from peak to peak
"H" is based on eave overhang (See Table 2)
The cable should be installed over the unheated portion of the roof (E in Fig. 1) - normally the roof area above the overhang.
To design how much cable is needed, multiply the length of the roof edge that you want cable on by the following spacing factor:
Cable Installation Patterns: |
Add this number calculated
above to the length of the downspout. (A in Figure 2). Note: If a
downspout is located anywhere other than at the end of the cable routing, that
downspout will require double length of cable (B in Figure 2). Add extra
cable for valleys (6' per valley, C in Figure 2) and around dormers (D in Figure 2) Example: 20 feet of roof, 24" overhang (therefore using overhang multiplier of 2.7), 1 downspout @ 10' at end of cable run, 1 valley, 1 dormer with 30' perimeter. Cable length = (28 x 2.7) + 10 + 6 + 30 = 100 feet. Select 100 feet. If there is excess cable it can be used in the valley or downspout. |
Accessories: | |
Fiberglass Cloth Tape. Fiberglass cloth tape roll with a pressure-sensitive adhesive backing. Fiberglass cloth tape roll with pressure-sensitive thermosetting silicone adhesive. 365° F (185°C) rated. 3/4" (1.9 cm) wide x 108 ft. (32.91 m) long roll. | |
Aluminum Foil Tape. High temperature tape roll with a pressure-sensitive adhesive backing. 2" (5.08 cm) wide x 150 ft. (54.86 m) long roll, 200° F (93°C) rated. |
EASYHEAT GFST-1 120V Plug-In Power Connection Kit. EASYHEAT Line Plug to Heating Cable. Plug Adapter Kit for SR Cable with 30 Ma ground fault circuit protection. For EasyHeat SR Series self-regulating cable. |
SRES End Seal Kit for Roof and Gutter Deicing and Pipe Tracing |
SRSRG Roof and Gutter Splice Kit for Roof and Gutter Deicing |
SRTCS Installation Kit for Pipe Tracing |
SRST Splice and "T" Kit for Pipe Tracing |
SRP Power Connection Kit for Roof and Gutter Deicing and Pipe Tracing |
250' self dispensing reel box |
Each connection kit contains detailed instructions for connecting the cable to power supplies and/or other heating cables. Since self-regulating heating cable varies its heat output in relation to the ambient temperature a thermostat may not be necessary for some freeze protection applications. This feature also allows you to overlap the cable with no more overheating worries. As the surrounding temperature increases, the heat of the SR cable decreases. When the temperature decreases, the cable heat increases along the length of the cable. |
Secure
Online Ordering Note: The cable is also available for sale by the foot below and is a custom order. Once the order is placed it cannot be cancelled or returned once you receive the cable. This is because the cable is cut to length here, or at EasyHeat, for your order, to your requested length. |
|||
Item ID | Catalog # | Description |
Click "Select" below to see the price and our actual real-time quantity in stock |
Roof and Gutter Applications: | |||
EASY10177 |
SR51J |
Cut-to-order, 5 w/ft, 120 VAC |
|
EASY10076 |
SR51J250 |
250' self dispensing reel, 5 w/ft, 120 volt |
|
EASY10598 | SR51J750 | 750' self dispensing reel, 5 w/ft, 120 volt | |
EASY10149 |
SR52J |
Cut-to-order, 5 w/ft, 208/240/277 VAC |
|
EASY10274 |
SR52J250 |
250' self dispensing reel, 5 w/ft, 208/240/277 volt |
|
EASY10585 | SR52J750 | 750' self dispensing reel, 5 w/ft, 208/240/277 volt | |
Roof and Gutter Accessories: | |||
EASY10056 |
SRP |
Heat shrink power/end connection kit |
|
EASY10081 |
SRES |
Heat shrink end seal kit (5) |
|
EASY10150 | SRSRG | Cable Splice kit | |
EASY10055 | DSH | Downspout Hanger Kit (2) | |
EASY10058 | ZH-C | Roof Clips and Spacers (25) | |
CHROM383355 | AT-1 | Roll of Aluminum Tape, 2" Wide x 150 ft Long | |
EASY10678 | GFST-1 | 120V Plug-In Power Connection Kit | |
Wet Location Pipe Cables: | |||
EASY10205 |
SR31J |
3w/ft. 120 VAC. cut-to-order |
|
EASY10227 |
SR31J250 |
250' self dispensing reel, 3w/ft. 120 VAC. |
|
EASY10228 |
SR32J |
3 w/ft, 240 VAC, cut-to-order |
|
EASY10318 |
SR32J250 |
250' self dispensing reel, 3 w/ft, 208/240/277 VAC |
|
EASY10177 |
SR51J |
5 w/ft, 120 VAC, cut-to-order |
|
EASY10076 |
SR51J250 |
250' self dispensing reel, 5 w/ft, 120 volt |
|
EASY10598 | SR51J750 | 750' self dispensing reel, 5 w/ft, 120 volt | |
EASY10149 |
SR52J |
5 w/ft, 208/240/277 VAC, cut-order |
|
EASY10274 |
SR52J250 |
250 self dispensing reel,5 w/ft, 208/240/277 volt |
|
EASY10585 | SR52J750 | 750' self dispensing reel,5 w/ft, 208/240/277 volt | |
EASY10219 |
SR81J |
8 w/ft, 120 VAC, cut-to-order |
|
EASY10628 |
SR81J250 |
250 self dispensing reel, 8 w/ft, 120 VAC |
|
EASY10644 | SR81J750 | 750' self dispensing reel, 8 w/ft, 120 VAC | |
EASY10229 |
SR82J |
8 w/ft, 240 VAC, cut-to order |
|
EASY10639 |
SR82J250 |
250' self dispensing reel, 8 w/ft, 208/240/277 VAC |
|
EASY10645 | SR82J750 | 750' self dispensing reel, 8 w/ft, 208/240/277 VAC | |
Pipe Accessories: | |||
EASY10056 |
SRP |
Heat shrink power/end connection kit |
|
EASY10082 |
SRST |
Heat shrink splice and "T" connection kit (2) |
|
EASY10081 |
SRES |
Heat shrink end seal kit (5) |
|
EASY10092 |
SRTCS |
Fiberglass application tape and caution signs |
|
EASY10150 | SRSRG | Cable Splice kit | |
EASY10678 | GFST-1 | 120V Plug-In Power Connection Kit | |
CHROM383355 | AT-1 | Roll of Aluminum Tape, 2" Wide x 150 ft Long | |
TAPE10004 | SM431 | 3/4" Fiberglass Cloth Tape, 3/4" x 36 yds | |
*This delivery time is for normal conditions and is subject to EasyHeat factory availability. |
EasyHeat is a registered trademark of Easy Heat, Inc.
We are a Distributor of Industrial, Commercial and Residential Heaters and Controls. Always consult manufacturers installation instructions for proper installation of the products or systems shown on this website. © Copyright 1999-2019 Mor Electric Heating Assoc., Inc. MOR
ELECTRIC HEATING ASSOC., INC. |